Please use this identifier to cite or link to this item:
http://cris.utm.md/handle/5014/103
DC Field | Value | Language |
---|---|---|
dc.contributor.author | GUȚUL, Vera I. | en_US |
dc.contributor.author | COLDA, Iolanda | en_US |
dc.contributor.author | GUȚUL, Vera G. | en_US |
dc.contributor.author | USTUROI, Liubovi | en_US |
dc.date.accessioned | 2019-12-23T12:46:01Z | - |
dc.date.available | 2019-12-23T12:46:01Z | - |
dc.date.issued | 2019-06 | - |
dc.identifier.citation | GUŢUL, Vera I., COLDA, Iolanda, GUŢUL, Vera G. et al. Comparative analysis of variable refrigerant flow systems and chiller-fan coil system for office buildings. In: Journal of Engineering Science. 2019, vol. 26(2), pp. 100-109. ISSN 2587-3474. eiSSN 2587-3482. | en_US |
dc.identifier.issn | 2587-3474 | - |
dc.identifier.uri | http://cris.utm.md/handle/5014/103 | - |
dc.description.abstract | The paper is dedicated to the technical and economic analysis of air-conditioning solutions for office buildings. În this paper two air conditioning systems were compared: the variable refrigerant flow (VRF) system and the chiller-fan coil system. Comparison of the technical and economic indicators was done using the "global cost" method. As a result of the analysis, it was found that: the energy saving in the air conditioning system to a great extent depends on building design solutions and the type of air conditioning system | en_US |
dc.language.iso | other | en_US |
dc.publisher | Technical University of Moldova | en_US |
dc.relation.ispartof | Journal of Engineering Science | en_US |
dc.subject | VRF | en_US |
dc.subject | air conditioning system | en_US |
dc.subject | chiller-fan coil system | en_US |
dc.subject | cooling power | en_US |
dc.subject | Global Cost | en_US |
dc.subject | cooling energy consumed | en_US |
dc.subject | economic effect | en_US |
dc.title | COMPARATIVE ANALYSIS OF VARIABLE REFRIGERANT FLOW SYSTEMS AND CHILLER-FAN COIL SYSTEM FOR OFFICE BUILDINGS | en_US |
dc.title.alternative | Analiza comparativă a sistemelor cu debit de agent frigorific variabil şi sistemul chiller-fan coil pentru clădirile de birouri | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.5281/zenodo.3249207 | - |
item.grantfulltext | open | - |
item.languageiso639-1 | other | - |
item.fulltext | With Fulltext | - |
Appears in Collections: | Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Gutul-V-JES-2019-2_pp-99-108.pdf | 1.09 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.